Core loss Test Equipment
1.Test range
1.1.Magnetic flux density: 10,000~15,000 GAUSS
1.2.Capacity of magnetizing force: 0~320AT
1.3.Core loss: 0~15W/KG
2.Dimension of sample: Input manually
2.1.Effective length of magnetic circuit: 16cm~40cm
2.2.Effective area of section: 12cm2~150cm2
3.Frequency: 25~400Hz
4.Programmable power supply: 1Φ 0.1~8V 200A 25Hz~400Hz
5.Test method: magnetizing force determined by constant magnetic flux density, eddy current loss and hysteresis loss
6.Result display: results of flux density, magnetizing force, eddy current loss and hysteresis loss are display on screen
of computer
7.Judgment: magnetizing force, eddy current loss and hysteresis loss are judged according to the maximum and minimum
limits of base file.
8.Accuracy: ±1%
9.Test time: About 20 sec. (excludes the time of workpiece placement and wiring)
10.data acquisition and processing system
10.1.Separate industrial computer
11.Software
11.1.The add, edit and delete function of base file
11.2.The add, edit, delete and print out function of test data
11.3.The read and calculate function of test data
12.We could offer multiple test equipments for different needs.